APPLICATION / BENCHTOP
<p>Set yourself up for testing success with our pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit (HI6522). Our high-performing benchtop meter is ready-to-use straight out of the box and is fully equipped with everything you need to test. Includes necessary modules, electrodes, solutions, and more.</p>
<ul>
<li>Precise and consistent. Achieve quick, accurate, and repeatable results</li>
<li>Reliable and efficient. Ensure quality and meet requirements with easy digital record keeping and increased traceability</li>
<li>Simple and straightforward. Intuitive navigation menus, built-in help guides, and video tutorials make testing hassle-free</li>
</ul>
<p>Fits seamlessly into any laboratory or industry environment.</p>
<p>Perfect for chemists, researchers, educators, food manufacturers, beverage producers, and metal finishers to name a few.</p>
<p>HI6522-02 (EU power plug) is supplied with HI6000 housing unit; HI6000-2 pH/ORP/ISE hardware module (installed); HI6000-3 EC hardware module (installed); HI1131B pH electrode; HI7662-TW temperature probe; HI7631233 EC & resistivity probe; pH 4.01 buffer solution, 2 sachets; pH 7.01 buffer solution, 4 sachets; pH 10.01 buffer solution, 2 sachets; electrode cleaning solution, 2 sachets; pH & ORP electrode storage solution (25 mL); 3.5M KCl electrolyte solution (30 mL); capillary pipette, 1 piece; 1413 μS/cm standard solution, 4 sachets; 5000 μS/cm standard solution, 2 sachets; 12880 μS/cm standard solution, 2 sachets; electrode rinse solution, 2 sachets; electrode holder with base plate, screw, cable holder clip (requires mounting); 24 VDC power adapter; USB-C to USB-A cable; meter quick reference guide; hardware modules quick reference guides and quality certificates; probes and meter quality certificate.</p>
<p> </p>
<table>
<thead>
<tr>
<th>Specification Name</th>
<th>Detail</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>Sku</strong></td>
<td>HI6522-02</td>
</tr>
<tr>
<td><strong>pH Range</strong></td>
<td>-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH</td>
</tr>
<tr>
<td><strong>pH Resolution</strong></td>
<td>0.1 pH; 0.01 pH; 0.001 pH</td>
</tr>
<tr>
<td><strong>pH Accuracy</strong></td>
<td>±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)</td>
</tr>
<tr>
<td><strong>Calibration Points</strong></td>
<td>Up to 5</td>
</tr>
<tr>
<td><strong>Calibration Type</strong></td>
<td>Automatic; Semiautomatic; Manual</td>
</tr>
<tr>
<td><strong>Standard Buffers</strong></td>
<td>Hanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)</td>
</tr>
<tr>
<td><strong>Custom Buffers</strong></td>
<td>Up to 5</td>
</tr>
<tr>
<td><strong>Custom Group</strong></td>
<td>Option to select from eight standard buffers and user-defined custom buffers</td>
</tr>
<tr>
<td><strong>First Calibration Point</strong></td>
<td>Offset or Point (user setting)</td>
</tr>
<tr>
<td><strong>Isopotential Point</strong></td>
<td>-2.000 to 20.000 pH</td>
</tr>
<tr>
<td><strong>mV Range</strong></td>
<td>-2000.0 to 2000.0 mV</td>
</tr>
<tr>
<td><strong>mV Resolution</strong></td>
<td>1 mV; 0.1 mV</td>
</tr>
<tr>
<td><strong>mV Accuracy</strong></td>
<td>±0.2 mV ±1 last significant digit</td>
</tr>
<tr>
<td><strong>mV Calibration</strong></td>
<td>Single point offset, ±2000.0 mV</td>
</tr>
<tr>
<td><strong>ISE Range</strong></td>
<td>1.0×10<sup>¯5</sup> to 300.0 ppt (g/L or mg/mL)<br>5.0×10<sup>¯3</sup> to 1.0×10<sup>5</sup> ppm (mg/L or µg/mL)<br>1.0 to 5.0×10<sup>7</sup> ppb (µg/L)<br>1.0×10<sup>¯7</sup> to 10.0 M (mol/L)<br>1.0×10<sup>¯4</sup> to 1.0×10<sup>4</sup> mmol/L<br>1.0×10<sup>¯6</sup> to 60.0 %w/v<br>5.0×10<sup>¯7</sup> to 5.0×10<sup>7</sup> user</td>
</tr>
<tr>
<td><strong>ISE Resolution</strong></td>
<td>1, 2, 3 significant digits</td>
</tr>
<tr>
<td><strong>ISE Accuracy</strong></td>
<td>±0.5% (monovalent ions); ±1% (divalent ions)</td>
</tr>
<tr>
<td><strong>ISE Calibration Points</strong></td>
<td>Up to 5</td>
</tr>
<tr>
<td><strong>ISE Calibration Type</strong></td>
<td>All Standards; Standard Group</td>
</tr>
<tr>
<td><strong>ISE Standards</strong></td>
<td>7 standard solutions available for each concentration unit</td>
</tr>
<tr>
<td><strong>ISE Custom Standards</strong></td>
<td>Up to 5</td>
</tr>
<tr>
<td><strong>ISE Custom Group</strong></td>
<td>Up to 5</td>
</tr>
<tr>
<td><strong>Conductivity Range</strong></td>
<td>0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm</td>
</tr>
<tr>
<td><strong>Conductivity Resolution</strong></td>
<td>0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm</td>
</tr>
<tr>
<td><strong>Conductivity Accuracy</strong></td>
<td>±1 % of reading or ±0.010 μS/cm, whichever is greater</td>
</tr>
<tr>
<td><strong>Conductivity Cell Constant</strong></td>
<td>0.0500 to 200.0000 /cm</td>
</tr>
<tr>
<td><strong>Conductivity Calibration Type</strong></td>
<td>Automatic; Manual</td>
</tr>
<tr>
<td><strong>Conductivity Calibration Points</strong></td>
<td>Single; Up to 5</td>
</tr>
<tr>
<td><strong>Conductivity Calibration Solutions</strong></td>
<td>84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm</td>
</tr>
<tr>
<td><strong>Resistivity Range</strong></td>
<td>1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm</td>
</tr>
<tr>
<td><strong>Resistivity Resolution</strong></td>
<td>0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm</td>
</tr>
<tr>
<td><strong>Resistivity Accuracy</strong></td>
<td>±1 % of reading or ±1 Ω•cm, whichever is greater</td>
</tr>
<tr>
<td><strong>Total Dissolved Solids (TDS) Range</strong></td>
<td>0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)</td>
</tr>
<tr>
<td><strong>Total Dissolved Solids (TDS) Resolution</strong></td>
<td>0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt</td>
</tr>
<tr>
<td><strong>Total Dissolved Solids (TDS) Accuracy</strong></td>
<td>±1 % of reading or ±0.01 ppm, whichever is greater</td>
</tr>
<tr>
<td><strong>Salinity Range</strong></td>
<td>0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale)</td>
</tr>
<tr>
<td><strong>Salinity Resolution</strong></td>
<td>0.01 PSU; 0.01 ppt; 0.1 %</td>
</tr>
<tr>
<td><strong>Salinity Accuracy</strong></td>
<td>±1 % of reading</td>
</tr>
<tr>
<td><strong>Salinity Calibration</strong></td>
<td>1 point, using 100 % salinity calibration solution (% scale only)</td>
</tr>
<tr>
<td><strong>Temperature Range</strong></td>
<td>−20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K</td>
</tr>
<tr>
<td><strong>Temperature Resolution</strong></td>
<td>0.1 °C; 0.1 °F; 0.1 K</td>
</tr>
<tr>
<td><strong>Temperature Accuracy</strong></td>
<td>±0.2 °C; ±0.4 °F; ±0.2 K</td>
</tr>
<tr>
<td><strong>Temperature Calibration</strong></td>
<td>Single point, adjustable</td>
</tr>
<tr>
<td><strong>Temperature Compensation</strong></td>
<td>For pH: Automatic; Manual<br>For Conductivity: Linear; Natural; Standard; Disabled</td>
</tr>
<tr>
<td><strong>Reference Temperature</strong></td>
<td>For Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)</td>
</tr>
<tr>
<td><strong>Temperature Coefficient</strong></td>
<td>For Conductivity: 0.00 to 10.00 %/°C</td>
</tr>
<tr>
<td><strong>Reading Mode</strong></td>
<td>Direct<br>Direct/Autohold<br>ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction<br>Conductivity Only: Direct/USP</td>
</tr>
<tr>
<td><strong>Basic View</strong></td>
<td>Measurement data; Measurement profile (if enabled); Stability status</td>
</tr>
<tr>
<td><strong>Simple GLP View</strong></td>
<td>Basic view information<br>For pH: pH Last calibration date, slope, offset (pH, Rel. MV – ISE Only)<br>For Conductivity: Last calibration date and offset</td>
</tr>
<tr>
<td><strong>Full GLP View</strong></td>
<td>Simple GLP Information; Calibration point details (pH, ISE, Conductivity, and Salinity)</td>
</tr>
<tr>
<td><strong>Graph View</strong></td>
<td>Basic view information; measurement versus time graph</td>
</tr>
<tr>
<td><strong>Table View</strong></td>
<td>Basic view information; Table with measurements updated every second</td>
</tr>
<tr>
<td><strong>Reading Stability Criteria</strong></td>
<td>Accurate; Medium; Fast</td>
</tr>
<tr>
<td><strong>Reading Sampling Rate</strong></td>
<td>1000 ms</td>
</tr>
<tr>
<td><strong>Logging Type</strong></td>
<td>Automatic; Manual; Autohold</td>
</tr>
<tr>
<td><strong>Logging Number of Records</strong></td>
<td>50,000 maximum per file and stores at least 1,000,000 data points per user</td>
</tr>
<tr>
<td><strong>Logging Automatic Interval</strong></td>
<td>1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes</td>
</tr>
<tr>
<td><strong>Logging Sample ID</strong></td>
<td>Incremental Mode; Manual</td>
</tr>
<tr>
<td><strong>Logging Export Option</strong></td>
<td>.CSV file format</td>
</tr>
<tr>
<td><strong>Connectivity USB-A</strong></td>
<td>2 ports<br>keyboard and/or printer input<br>USB Flash Drive</td>
</tr>
<tr>
<td><strong>Connectivity USB-C</strong></td>
<td>1 port<br>PC Connectivity and USB-C Type Flash Drive</td>
</tr>
<tr>
<td><strong>Connectivity Wi-Fi & Ethernet</strong></td>
<td>FTP; Web Server (Log transfer and download); Email</td>
</tr>
<tr>
<td><strong>Connectivity RS232</strong></td>
<td>Connecting peripherals</td>
</tr>
<tr>
<td><strong>Calibration Reminder</strong></td>
<td>Daily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled</td>
</tr>
<tr>
<td><strong>Users</strong></td>
<td>Up to 9 users and the default administrator account</td>
</tr>
<tr>
<td><strong>Power Supply</strong></td>
<td>DC adapter 100-240 VAC to 24 VDC 2A</td>
</tr>
<tr>
<td><strong>Environment</strong></td>
<td>0 to 50 °C / 32 to 122 °F / 273 to 323 K maximum 95 % RH non-condensing</td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td>205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)</td>
</tr>
<tr>
<td><strong>Weight</strong></td>
<td>8.05 lbs</td>
</tr>
</tbody>
</table>